SKD2 Flow Control Switch

Automatic flow control switch for single-phase pump systems — starts the pump when pressure drops (taps opening) and stops it when flow ceases (taps closing or water shortage). Handles 0–6 m³/h flow, up to 10 bar, for drinking water or non-potable piping. Adjustable cut-in pressure between 1.2 and 1.5 bar.

View Catalogue

Category:

Description

Overview

This flow control switch automatically starts the pump when pressure decreases (for example, when a tap is opened) and stops it when there’s no flow or a water shortage (for example, when a tap is closed). It’s suitable for both drinking water and non-potable water piping systems.

Operating limits

  • Flow: 0 to 6 m³/h
  • Pipe water temperature: 0–60°C (not frozen)
  • Ambient temperature: 0–45°C

Technical specifications

Model Input Voltage (V) Frequency (Hz) Current (A) Power (W) Power (HP)
SKD-2 220 50 10 1500 2
  • Starting pressure: 1.5 bar
  • Maximum pressure: 10 bar
  • Cut-in pressure adjustable between 1.2 and 1.5 bar
  • Protection grade: IP65
  • Inlet/outlet size: 1″ x 1″ BSP

Construction

  • Reinforced nylon (PA6+GF30%) body components
  • EPDM membrane
  • Ferrite magnet
  • Brass (H59) fittings
  • Replaceable PC board

Additional information

Brand

Vega